The trigger info recorded for each trigger is:

GPS triggers record the absolute time in addition to this information.

Table: Trigger types as recorded by the trigger

trigger-type (HEX) Function
000:000:001 ID singles trigger
000:000:002 ID history trigger
000:000:004 5 inch trigger
000:000:008 1pps trigger
000:000:010 Acquire trigger: forced acquisition A *
000:000:020 Acquire trigger: forced acquisition B *
000:000:030 Acquire trigger: clock acquisition A *
000:000:040 Acquire trigger: clock acquisition B *
000:000:050 Acquire trigger: test pulser acquisition A *
000:000:060 Acquire trigger: test pulser acquisition B *
000:000:070 Acquire trigger: pedestal acquisition A *
000:000:080 Acquire trigger: pedestal acquisition B *
000:000:090 Acquire trigger: test pulser followed by forced acquisition A *
000:000:0a0 Acquire trigger: test pulser followed by forced acquisition B *
000:000:0b0 Acquire trigger: test pulser no acquisition *
000:000:100 ID prescale trigger
000:000:200 GPS trigger
000:000:400 Delayed calibration trigger
000:000:800 Supernova trigger
000:001:000 ID calibration forced trigger: source 1 #
000:002:000 ID calibration forced trigger: source 2 #
000:003:000 ID calibration forced trigger: source 3 #
000:004:000 ID calibration forced trigger: source 4 #
000:005:000 ID calibration forced trigger: source 5 #
000:006:000 OD calibration forced trigger: source 1 #
000:007:000 OD calibration forced trigger: source 2 #
000:009:000 ID calibration global trigger: source 1 #
000:00a:000 ID calibration global trigger: source 2 #
000:00b:000 ID calibration global trigger: source 3 #
000:00c:000 ID calibration global trigger: source 4 #
000:00d:000 ID calibration global trigger: source 5 #
000:00e:000 OD calibration global trigger: source 1 #
000:00f:000 OD calibration global trigger: source 2 #
000:010:000 Macro singles trigger
000:020:000 Macro coincidence trigger
000:040:000 Macro random trigger
000:080:000 Macro muon trigger
000:100:000 OD top singles trigger
000:200:000 OD upper side singles trigger
000:400:000 OD lower side singles trigger
000:800:000 OD bottom singles trigger
001:000:000 ID delayed trigger
002:000:000 ID prompt trigger
004:000:000 OD to ID trigger
008:000:000 ID to OD trigger
010:000:000 OD top history trigger
020:000:000 OD upper side history trigger
040:000:000 OD lower side history trigger
080:000:000 OD bottom history trigger
400:000:000 Disable trigger
800:000:000 Enable trigger
1000:000:000** Macro calibration trigger
2000:000:000** Macro to ID trigger
4000:000:000** Run condition change trigger
8000:000:000** 1pps global acquisition trigger

* Can not occur at the same time

# Can not occur at the same time

** board3 version = 12 only